M.A. Ulherr, E.M.H. White, F. Lanoy, M. Rudolphi, M. Krüger, M.C. Galetz
Materials and Corrosion (2026), DOI: 10.1002/maco.70249
Vanadate corrosion occurs in devices powered by heavy fuel oil, such as stationary turbines. To avoid this aggressive attack from molten V2O5, inhibitors like fuel-dissolvable Ca-species are usually added beforehand to the fuel to bind V2O5 as higher-melting vanadates during combustion. However, this requires a constant addition of inhibitors and increased maintenance due to the accumulation of slag on the turbines, resulting in higher costs. As an alternative strategy, here the inhibitor is directly incorporated into a protective coating to be applied and available exactly where it is necessary. In this study, three Ca-based coatings were investigated for their potential to mitigate vanadate corrosion at 600°C and 700°C. The various coatings showed promising protective properties for up to ~500 h, demonstrating suppression of the salt fluxing mechanism by the formation of higher melting vanadates, especially CaV2O6. Additionally, during the sintering of the coatings, a Ca-Si-Ni intermetallic phase formed, that was identified as a potentially highly protective phase against molten V2O5.